DUAL30 load bank
31.5kW | 120V/240V or 60/120V, AC 1-phase/DC
Product information
Operating and maintenance manual
General arrangement drawing
Product datasheet
Technical Specification
Ratings
DC or 1-phase AC
Voltage 2 version available; 120 & 240 V or 60 & 120V
Frequency 50 or 60 Hz
Resolution 0.5kW
Maximum capacity 31.5kW
Control and Ventilation
Manual controls
12 x on/off push buttons for load sections,
1 x link bar to select between lower and higher voltage operation
Control interface
Manual Control (described above)
6 x load section lamps
1 x control supply healthy lamp
1 x analogue voltmeter
1 x analogue ammeter
Cooling Forced convection, horizontal orientation
Fans 1 x AC fan, axial type
Control supply 110V or 230V 1-phase AC
Source External seperate supply required for fan and controls
Load connections
4 x M16 brass threaded studs (1P/+, 2 x voltage links, N/-)
External control supply
1 x C14 socket for 230V AC (L+N+PE)
1 x socket for 110V AC (L+N+PE)
Measurement points
2 x panel mounted 4mm banana sockets for external current measurement
Connection Interfaces
Suitable for indoor use only
Ambient temperature -5°C to 40°C
Humidity 95% RH
Ingress protection IP20
Operating Environment
Resistor elements Expanded mesh and wound steel tape
Element material High grade stainless steel
Enclosure Aluminium; painted (RAL9002) grey
Portability
3 x handles
4 x castor wheels
Construction
Weight and Dimensions
Length 600mm
Width 500m
Height 800mm
Weight 50kg
Thermal protection over temperature thermostat cut-out
Safety
Optional extras
Supply cables made to order to the desired length and with supply side connection method to suit the intended use.
Protective PVC cover available for additional protection during transport or storage
Measurement leads with 4mm banana plugs for voltage and current feed to external meter.