DC110 load bank

Product support page

Product information

 

Operating and maintenance manual .PDF

Product data sheet .PDF

Technical specification

Ratings

Voltage 28V DC

Maximum capacity 3.36kW

Current range 0.6 to 120 A

 

Control and Ventilation

Manual controls

6 x Load section toggle switch

1 x Rheostat variable section control

Control interface

Manual controls (described above)

1 x Current shunt with 100A/100mV ratio

Cooling Forced convection, horizontal orientation

Fans 2 x DC axial type

Control supply 24V DC

Source Internal, taken from supply under test


Load controls 2 x Quick release connectors (1 cable set included)

Measurement connections 2 x 4mm Banana sockets

Connection Interfaces


Suitable for Indoor use only

Ambient temperature -10°C to 50°C

Humidity 95% RH

Ingress protection IP20

Operating Environment


Construction

Resistor elements Wound steel tape

Element material High grade stainless steel

Enclosure Aluminum, painted RAL9002 grey

Portability 1 x protective lid with integrated carry handle


Weight and Dimensions

 

Length 400mm
Width 200mm
Height 500mm
Weight 10kg


Electrical protection Over current and short circuit fuse protection

Safety

 Optional extras


Additional supply cables available in 5m lengths as standard or made to custom length if requested, with supply side connection method to suit the intended use.

Protective PVC cover available for protection during transport or storage.